City of Pomona, USA, Proposes Award of $486,500 Sewer Manhole Rehabilitation Project
en.Wedoany.com Reported - On November 16, the Pomona City Council agenda in California, USA, included the award of a contract for sewer manhole and pipeline rehabilitation, proposing to award a $486,500 construction contract to Ayala Engineering. The project number is 86027, with funding including $344,000 transferred from the sewer fund reserve. The work primarily targets aging sewer manholes within roadways and access easements, involving interior concrete repair, anti-corrosion protection, and structural liner renewal.
According to the bidding technical documents, the base scope of work covers approximately 30 manholes, with 3 additional rehabilitation options. The manholes are approximately 4 feet (1.22 meters) in diameter, with depths including both 10 feet (3.05 meters) or less and greater than 10 feet. Prior to construction, sediment within the manholes must be cleaned out, surface sandblasting performed, and damaged concrete and invert channels repaired, followed by application of calcium aluminate cement mortar or polyurethane protective coating depending on structural conditions.
Some manholes also require installation of precast polymer concrete liners, involving installation of special-sized components and treatment of existing internal structures. Additional work also includes temporary sewage bypass pumping, contaminated soil removal and disposal, frame and cover replacement, and continuous 7-day sewage flow monitoring at designated manholes. Sewage conveyance must be maintained during construction to avoid rehabilitation work affecting normal operation of the pipeline network.
Interior coatings for manholes are primarily used to protect concrete structures and reduce chemical attack, abrasion, and leakage in sewage environments. According to U.S. EPA information, hydrogen sulfide in sewage systems can convert to sulfuric acid and corrode concrete and metal components; therefore, surface preparation, material adhesion, and post-rehabilitation quality inspection are important aspects of such projects.
The base work is scheduled for completion within 85 consecutive working days after receipt of notice to proceed, with additional work subject to a separate construction period of up to 25 consecutive working days. The City Council also proposes to disqualify 3 bidders whose bid documents do not meet certification requirements and to review the contract award recommendation for Ayala Engineering.