Complete meter and sensor
| Maximum flow velocity | 15m/s | ||||
| Accuracy (see accuracy curve) |
DN15~DN600 | ±0.3% of reading (velocity ≥1m/s), ±0.2%** | |||
| ±3mm/s (velocity <1m/s) | |||||
| DN700~DN3000 | ±0.5% of reading (velocity ≥0.8m/s) | ||||
| ±4mm/s (velocity <0.8m/s) | |||||
| Fluid conductivity | ≥5μs/cm | ||||
| Nominal pressure | DN15~DN150 | 4.0MPa | |||
| DN15~DN600 | 1.6MPa | ||||
| DN200~DN1000 | 1.0MPa | ||||
| DN700~DN3000 | 0.6MPa | ||||
| Ambient temperature | Sensor | -25℃~+60℃ |
|||
| Converter and integrated type | -10℃~+60℃ |
||||
| Lining material and maximum fluid temperature | Lining material | Separated type | Integrated type | ||
| Polytetrafluoroethylene | 100℃;150℃(special order required) | 70℃ | |||
| Polyfluoroethylene | 100℃;150℃(special order required) | 70℃ |
|||
| Polyperfluoroethylene propylene | 100℃;150℃(special order required) | 70℃ | |||
| Polychloroprene rubber | 80℃;120℃(special order required) | 70℃ | |||
| Polyurethane | 80℃ | 70℃ | |||
| Signal electrode type | Fixed type (DN15~DN2600), scraper type (DN300~DN1600) | ||||
| Signal electrode and ground electrode materials | Molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium, tantalum, platinum-iridium alloy, stainless steel coated with tungsten carbide | ||||
| Connecting flange material | Carbon steel | ||||
| Grounding flange material | Stainless steel 1Cr18Ni9Ti | ||||
| Inlet protection flange material | DN15~DN600 | Stainless steel 1Cr18Ni9Ti | |||
| DN700~DN3000 | Carbon steel | ||||
| Enclosure protection | DN15~DN150 separated type rubber or polyurethane lined sensor | IP65, IP68 (special order) | |||
| DN200~DN2600 separated type rubber or polyurethane lined sensor | IP68 underwater 10 meters | ||||
| Other sensors and all converters | IP65 | ||||
| Distance (separated type) | Converter to sensor generally not exceeding 100m; over 100m requires special order | ||||
| *DN700~DN2600, special order accuracy can reach ±0.3% of reading (velocity 1m/s) or ±3mm (velocity <1m/s), *0.2% accuracy flowmeter can be specially provided |
|||||