The S22(20)-M-30-2500kVA three-phase oil-immersed fully sealed distribution transformer, unlike ordinary oil-immersed transformers, eliminates the oil conservator and uses the corrugated fins on the oil tank for heat dissipation and cooling. The corrugated design compensates for the expansion and contraction of the oil volume. This series of products is suitable for 10kV, 20kV, and 35kV distribution systems and can be used for residential areas, commercial streets, industrial and mining enterprises, as well as rural power and lighting.
S22(20) series oil-immersed distribution transformer
Product Introduction
Product Parameters
Table 1: Main technical parameters of S22-M type fully sealed power transformer
|
Project Capacity kVA |
Voltage combination |
Vector group Symbol |
No-load Current (%) |
No-load Loss (W) |
Impedance Voltage (%) |
Load Loss (W) |
||
|
High Voltage(kV) |
High Voltage Tap Range |
Low Voltage(kV) |
||||||
|
30 |
6 6.3 10 10.5 |
± 2 × 2.5% ± 5% |
0.4 |
Yyn11 |
0.4 |
65 |
4 |
455 |
|
50 |
0.4 |
80 |
655 |
|||||
|
63 |
0.4 |
90 |
785 |
|||||
|
80 |
0.35 |
105 |
945 |
|||||
|
100 |
0.35 |
120 |
1140 |
|||||
|
125 |
0.35 |
135 |
1360 |
|||||
|
160 |
0.30 |
160 |
1665 |
|||||
|
200 |
0.30 |
190 |
1970 |
|||||
|
250 |
0.30 |
230 |
2300 |
|||||
|
315 |
0.30 |
270 |
2760 |
|||||
|
400 |
0.25 |
330 |
3250 |
|||||
|
500 |
0.25 |
385 |
4.5 |
3900 |
||||
|
630 |
0.25 |
460 |
4460 |
|||||
|
800 |
0.20 |
560 |
5400 |
|||||
|
1000 |
0.20 |
665 |
7415 |
|||||
|
1250 |
0.20 |
780 |
8640 |
|||||
|
1600 |
0.20 |
940 |
10440 |
|||||
Table 2: Main Technical Parameters of S20-M Type Fully Sealed Power Transformer
|
Project Capacity kVA |
voltage combination |
Vector group Symbol |
No-load Current (%) |
No-load Loss (W) |
Impedance Voltage (%) |
Load Loss (W) |
||
|
High voltage(kV) |
High voltage tap range |
Low voltage (kV) |
||||||
|
30 |
6 6.3 10 10.5 |
± 2 × 2.5% ± 5% |
0.4 |
Dyn11 Or Yyn0 |
0.28 |
70 |
4 |
505 |
|
50 |
0.25 |
90 |
730 |
|||||
|
63 |
0.23 |
100 |
870 |
|||||
|
80 |
0.22 |
115 |
1050 |
|||||
|
100 |
0.21 |
135 |
1265 |
|||||
|
125 |
0.20 |
150 |
1510 |
|||||
|
160 |
0.19 |
180 |
1850 |
|||||
|
200 |
0.18 |
215 |
2185 |
|||||
|
250 |
0.17 |
260 |
2560 |
|||||
|
315 |
0.16 |
305 |
3065 |
|||||
|
400 |
0.16 |
370 |
3615 |
|||||
|
500 |
0.15 |
430 |
4330 |
|||||
|
630 |
0.15 |
510 |
4.5 |
4960 |
||||
|
800 |
0.14 |
630 |
6000 |
|||||
|
1000 |
0.13 |
745 |
8240 |
|||||
|
1250 |
0.12 |
870 |
9600 |
|||||
|
1600 |
0.11 |
1050 |
11600 |
|||||
Other products from this supplier

SVR Line Automatic Voltage Regulator

KYN28 type high-voltage switchgear

DWK-type Pole-mounted Automatic Reactive Power Compensation Device

Skid-mounted substation

10kV Distribution Network Series Compensation Device

TBB-type high-voltage automatic reactive power compensation device

IPSVR Intelligent Line Voltage Regulator

Box-type substation

HSVG High-Voltage Static Var Generator

GGD type low-voltage switchgear

Landscape media box-type transformer

GCS type low-voltage withdrawable switchgear
Related Products
Power Transformer
KYN28 - High Voltage Switchgear
Primary-Secondary Integrated Pole-Mounted Circuit Breaker (Standard Type)
Vacuum Interrupter
QLG-12/24 SF GAS INSULATED RING MAIN UNIT
Epoxy resin vacuum casting dry-type transformer
220kV Composite Outdoor Cable Terminal
220kV and Below Series Power Transformers
fuel gas power generation ( covered with net)
Outdoor High-Voltage Integrated Primary and Secondary Circuit Breaker LW3-12
72.5kV 1250A 31.5kA SF6 free Gas-insulated Metal-enclosed Switchgear