ZDL97 series turbine flow meter
Negotiable
China
Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
+86 18526430909
Online Contact
Favorite
Product Introduction

The turbine flow meter is a new generation of high-precision, high-reliability gas metering instrument, developed based on advanced domestic and international flow meter technology. It incorporates optimization design and integrates theories of aerodynamics, fluid mechanics, and electromagnetics. The device combines temperature, pressure, flow sensors, and an intelligent flow integrator. It offers excellent metering performance at both low and high pressures, multiple signal output options, and low sensitivity to fluid disturbances.

The turbine flow meter, a key type of rotor-based flow (speed) meter, is characterized by its simple structure, fewer processed components, lightweight design, ease of maintenance, high flow capacity (it allows larger flow through the same diameter), and suitability for high-parameter environments (high temperature, high pressure, and low temperature). It is widely used in the measurement of petroleum, gas, natural gas, liquefied gas, inorganic liquids, and organic liquids.

Product Parameters

Technical parameters:

① Accuracy grade: 0.5, 1.0

② Nominal diameter: DN4 ~ DN400

③ Pressure rating: 1.6 ~ 32Mpa

④ Medium temperature:-80 ~ 300℃ (normal supply -20 ~ 90℃)

⑤ Working temperature:-20 ~ 50℃

⑥ Output mode: voltage pulse, low level ≤ 1V, high level ≥ 6V; 4 ~ 20mA (24V two-wire system)

⑦ Protection grade: IP65

⑧The output signal: 4~20mADC

Selection table:

ZDL97

Selection code

Description

Instrument Type

A

High precision, high stability

B

High stability

Sales mode

C, D, W (The selection personnel can be ignored)

Connection form

1

Threaded connection

2

Flange clamp

3

Flange connection

T2

Special requirements

Power

D

DC12 ~ 36V

A

AC220V ± 15%

T3

Special requirements

Span Specification

A

Standard Range

B

Extended range

C

Special Range

Accuracy

1

1.0%

2

1.5%

Output mode

P1

4 ~ 20mA

P2

Pulse output

Nominal diameter

 

Customers fill in options DN4 ~ DN400

Explosion-proof grade

1

ExdIIBT6

T4

Special requirements

Sensor material

S

304 stainless steel

L

Cast aluminum

Core component material

1

Anti-corrosion ABS impeller

2

aluminum alloy impeller

Selection example

ZDL97 A1AA1 P1101S2