Technical parameters:
Maximum range: 30m
Measurement accuracy: ± 10mm
Process temperature:(-40~130)℃ (-60~250)℃
Process pressure:(-0.1~4) MPa
Frequency: 26G
Process connection: thread G1½A, flange
Material:
-Antenna: PTFE, PP
-Flange: stainless steel 316L
-Enclosure.: aluminum, stainless steel 316L
-Sealing between the enclosure and the enclosure cover.: silicone rubber
-Ground terminal: Stainless steel
Supply voltage:
Two-wire system-Standard type: 15 ~ 36VDC
-Intrinsically safe type: 15 ~ 30VDC
Four-wire system-intrinsically safe + explosion-proof: 24VDC ± 10%,220VAC ± 10%
Output parameters:(4~20)mA/HART two-wire system
Selection table:
|
ZDW91 |
Selection code |
Description |
|
Grade |
A |
High precision, high stability |
|
B |
High stability |
|
|
Explosion-proof grade |
P |
Standard type (without explosion-proof) |
|
I |
Intrinsic safety type (ExiaIICT6)(Aluminum housing only) |
|
|
C |
Intrinsic safety type + marine license (Ex ia II CT6). |
|
|
G |
Intrinsic safety type + explosion-proof type (Ex d[ia] II CT6). |
|
|
Electronic components |
A |
4 ~ 20mA two-wire system |
|
B |
4~20mAHART two-wire system |
|
|
C |
4 ~ 20mA/24VDC ± 10%, 220VAC ± 10%/four-wire system |
|
|
D |
4 ~ 20mA/24VDC ± 10%, 220VAC ± 10%/HART four-wire system |
|
|
T1 |
Special requirements |
|
|
Process Connection |
GP |
Thread G1/₂ A |
|
KP |
Thread G2A |
|
|
FA |
Flange DN50PN4.0 stainless steel 316L (GB/T9119-2000) |
|
|
FB |
Flange DN80PN1.6 stainless steel 316L (GB/T9119-2000) |
|
|
FC |
Flange DN100PN1.6 stainless steel 316L (GB/T9119-2000) |
|
|
FE |
PETE flanged flange DN50PN1.6 stainless steel |
|
|
FF |
PETE flanged flange DN80PN1.6 stainless steel |
|
|
FG |
PETE flanged flange DN100PN1.6 stainless steel |
|
|
FI |
PETE flanged flange DN150PN1.6 stainless steel |
|
|
FJ |
Flanged universal joint DN80 (for rod antennas only) |
|
|
FK |
Flanged universal joint DN100 (for rod antennas only) |
|
|
FL |
Flanged universal joint DN150 (for rod antennas only) |
|
|
T2 |
Special requirements |
|
|
Seal/Process Temperature |
A |
Viton/-40~130℃ |
|
B |
Kalrez/-20~130℃ |
|
|
C |
Viton/-40~200 ℃ with heat sink |
|
|
D |
Kalrez/-20~200 ℃ with heat sink |
|
|
T3 |
Special requirements |
|
|
Enclosure/Degree of Protection |
A |
Aluminum/IP67 |
|
D |
Aluminum two-chamber/IP67 |
|
|
G |
Stainless Steel 316L/IP67 |
|
|
T4 |
Special requirements |
|
|
Cable entry |
M |
M20 × 1.5 |
|
N |
1/2NPT |
|
|
T5 |
Special requirements |
|
|
Field Display/Programming |
A |
Have |
|
X |
None |
|
|
Selection example |
ZDW91 B P A K P B A M A |
|
|
Ordering Method |
C D W the selection personnel can ignore it. |
|


京公网安备 11010802043282号