TH-2004H Infrared Absorption Carbon Monoxide Analyzer

EXW
$0.15-0.29 /Unit
China
No.11 Huashiyuan North Road, East Lake High-tech Development Zone, Wuhan City, Hubei Province
02787923722
Online Contact
Favorite
Product Introduction

Instrument Principle

The instrument adopts the gas filter correlation infrared absorption method. The basic working principle is: CO has absorption characteristics for infrared radiation at a specific wavelength (4.67 μm), and the strength of absorption is related to the CO concentration. The detection method is: infrared light from the infrared light source sequentially passes through the CO and N2 filters in the rotating filter wheel, then enters the optical cell through a narrow-band interference filter. Infrared light passing through the CO filter in the filter wheel is absorbed and cannot absorb CO in the sample gas in the optical cell, forming the reference light intensity. Infrared light passing through the N2 filter in the filter wheel is not absorbed and irradiates the sample gas in the optical cell. When CO in the sample gas absorbs infrared radiation, it forms the measurement light intensity that passes through the optical cell and irradiates the infrared detector. Through the light intensity ratio of the two, the concentration of CO in the sample gas is calculated using the Lambert-Beer law.

Instrument Features

•   Adopts 7-inch full-touch color screen, monitoring values can be switched freely between ppb, ppm, μg/m³, mg/m³;

•   Chinese menu-style operation interface, easy to operate;

•   With automatic range switching function;

•   Monitoring values can be displayed graphically, and graphic curves can be freely zoomed;

•   With automatic temperature and pressure compensation function;

•   Adopts adaptive optimization algorithm to achieve optimal response time and signal-to-noise ratio;

•   Supports remote calibration and remote diagnosis of internal working parameters;

•   Massive historical data storage, one year of valid data, query and output functions (one record every 5 minutes);

•   With multi-parameter alarm function;

•   Correlation wheel made with special process for long-term use.

Product Parameters

Measurement Method

Gas Filter Correlation Infrared Absorption Method

Response Time (T90)

<150s

Range

(0~50)ppm

(including 0~10, 20, 30ppm or more)

Zero Drift

±0.1ppm/24h

Span Drift

±0.25ppm/24h (20% span drift)

Zero Noise

0.05ppm

±0.25ppm/24h (80% span drift)

Span Noise

≤2ppb

Sample Flow Rate

(900±10%) mL/min

Indication Error

<1% F.S

Digital Output

RS232/RS485/USB/Ethernet

Repeatability

<0.5%

Analog Output

 

(0~1)V (0~5)V (0~10)V

Linearity

±1% F.S

(0~20)mA (4~20)mA optional

Operating Ambient Temperature

(15~35)℃

Minimum Resolution

0.01ppm

Dimensions

(430×570×225) mm

Weight

13kg