Mobile Power Supply Vehicle

Negotiable
China
No. 258 Xupan Road, Xuhang Town, Jiading District, Shanghai City
13917000520
Online Contact
Favorite
Product Introduction

Flexible Energy Solutions - Say Goodbye to Power Anxiety

All-in-One Mobile Energy Platform
One vehicle is a mobile green energy station.
Plug and Play: Drive to the site, connect and power up instantly, no waiting, no infrastructure needed.
Multi-Energy Integration: Optional AC/DC conversion equipment available to meet diverse, composite energy demands across various scenarios.
Smart & Green: Utilizes clean battery energy storage, operates quietly with zero emissions, and features intelligent scheduling to help you save money.

Core Advantages

  • Fast: 4-6 minute ultra-fast battery swap. Industry-leading robotic battery swap technology with low parking precision requirements.
  • Economical: 96% peak system efficiency. Performs peak shaving and valley filling, utilizes off-peak electricity for charging, significantly reducing energy costs.
  • Broad Compatibility: Compatible with mainstream battery models. Dual-platform support for power batteries/energy storage batteries, with flexible capacity configuration (500-2000kWh).
  • Intelligent: Managed via a smart cloud platform. Features remote real-time monitoring and fault prediction, putting energy management at your fingertips.
  • Stable: Multiple layers of safety protection. High protection rating, adaptable to various harsh environments, ensuring safety and reliability.
Product Parameters

Technical Parameters of Battery Swap Vehicle

Applicable models

Heavy truck

Power change mode

Ceiling type

Power change time

≤ 6min

Matching battery exchange

282/350/400

Equipment Service Capability

168 trips/24H

Use temperature range

-45 ℃ ~ 70 ℃

Use humidity range

5%-95%RH

Use Altitude

Standard version: ≤ 2000m High altitude: ≤ 4000m

Wind resistance grade

≤ Level 12

Seismic grade

Seismic fortification intensity ≤ 7 degrees, ≤ 0.15g

Start mode

Code scanning, one-key start

Operation mode

Full-automatic power exchange, station-side supervision and cloud monitoring of Enneagon

Whole station protection

Gull-wing door design, LED display, voice prompts

Applicable Scenarios

Full scene

EMS Energy Management System Parameters

1. Hardware parameters industrial-grade server \industrial control computer, recommended configuration

Processor

Quad-core 3.1GHz or above

Memory

More than 16GB

Hard disk

Above 500G

Display

Discrete graphics card with at least VGA connector

Ethernet

Motherboard provides at least two 10/100/1000Mbps Ethernet controllers

I/O Interface

At least 4 RS232/485 interfaces; At least two USB2.0 interfaces

Extension

Support PCI/PCIe/mini PCIe expansion

2. Software parameters

Category

Subkey

Requirements

Operational response performance

Page Switch

Less than 1 second

Historical Data Query

Less than 3 seconds

Report File Export

Less than 5 seconds

Data Communication Performance

Control command issued

Less than 1 second

Real-time alarm pops up

Less than 3 seconds

Remote message refresh time

Less than 5 seconds

Telemetry Refresh Time

Less than 10 seconds

Operational response performance

Processor Occupancy

Average less than 50%

Memory footprint

Average less than 60%

Network bandwidth

Average less than 30%

Data Communication Performance

Event Logging

More than 10 years

Data logging

Greater than 1 year

System alarm and fault

More than 5 years

System Control Commands

More than 5 years

Remote signaling displacement

More than 3 years

Configuration changes

permanent preservation

Xiaojiu power car system technical parameters

Project

Specifications

Remarks

Equipment Model

EMPS-770-E400

 

Number of work

2/4/6/8

Optional

Base

Applicable to power assembly of upper frame of line nine

Customizable

Equipment installation dimensions

13000*2500mm (L*W) (H≤1500mm)

8 station size

Equipment weight

About 40T with battery

8 station weight

Elevation

≤2000 m

Use over frequency reduction

Relative humidity

5% to 95%

 

Operating ambient temperature

-30°C ~ 50°C

Alpine version

Wind resistance grade

Non-working level ≤ 12, working level ≤ 8

 

Lightning protection performance

Equipped with vehicle grounding grid and grounding pin multi-point grounding electrode and surge protector

 

Insulation performance

Communication/V2G power cabinet: 220/380VAC, insulation resistance ≥ 0.5MΩ; DC-DC power cabinet: 1000VDC, insulation resistance ≥ 10MΩ;

 

IP Level

V2G power cabinet/DC-DC power cabinet/communication power cabinet: IP54; power battery box (after connection): IP67

 

seismic performance

Seismic fortification intensity: 7 degrees, 0.15g

 

Noise performance

Overall noise less than 75dB

 

Design life

5 years

 

EMS Energy Management System Parameters

1. Hardware parameters industrial-grade server \industrial control computer, recommended configuration

Processor

Quad-core 3.1GHz or above

Memory

More than 16GB

Hard disk

Above 500G

Display

Discrete graphics card with at least VGA connector

Ethernet

Motherboard provides at least two 10/100/1000Mbps Ethernet controllers

I/O Interface

At least 4 RS232/485 interfaces; At least two USB2.0 interfaces

Extension

Support PCI/PCIe/mini PCIe expansion

2. Software parameters

Category

Subkey

Requirements

Operational response performance

Page Switch

Less than 1 second

 

Historical Data Query

Less than 3 seconds

 

Report File Export

Less than 5 seconds

Data Communication Performance

Control command issued

Less than 1 second

 

Real-time alarm pops up

Less than 3 seconds

 

Remote message refresh time

Less than 5 seconds

 

Telemetry Refresh Time

Less than 10 seconds

Operational response performance

Processor Occupancy

Average less than 50%

 

Memory footprint

Average less than 60%

 

Network bandwidth

Average less than 30%

Data Communication Performance

Event Logging

More than 10 years

 

Data logging

Greater than 1 year

 

System alarm and fault

More than 5 years

 

System Control Commands

More than 5 years

 

Remote signaling displacement

More than 3 years

 

Configuration changes

Permanent preservation

Technical parameters of DC-DC power cabinet

Rated power

320kW

DC current input voltage

250 ~ 825VDC

Peak Efficiency

97%

Connection mode

High voltage connector

Charging mode

Dual simultaneous output, parallel charging, support switching charging gun output

External Gun Line

Support 1 machine 2 guns

Support Standards

National Standard

Rated output current

500A

Output voltage

200 ~ 1000VDC (high voltage mode)

Auxiliary power supply (power supply for vehicle BMS)

1.0 level

DC watt-hour meter accuracy class

Code scanning, one-key start

DC insulation monitoring

Insulation value <500 Ω/V below the alarm, can be charged, insulation value <100 Ω/V below the charging is prohibited

Protection level

IP54

Cooling mode

Intelligent air cooling

PCS power cabinet technical parameters

 

Project

Parameters

Environmental parameters

Operating temperature range

-20 ℃-60 ℃ (above 45 ℃)

Altitude

2000m (derating over 2000m)

Relative humidity

0-95%

Basic parameters

Rated power

320kW

Heat dissipation mode

Air-cooled, independent air duct

Upper computer communication interface

CAN/RS485

BMS communication interface

CAN/RS485

Protection level

IP65

AC parameters

Anti-corrosion grade

C5

Rated voltage

320V/380V

Type of grid connection

Three-phase three-wire compatible three-phase four-wire system

Rated frequency

50Hz

Rated current

450A

Maximum current

500A

Power factor

> 0.99

THDi

<3%

DC component

<0.5%In

Efficiency

≥ 98% (maximum)

DC parameter

Operating voltage range

550V-1000V

Maximum charging and discharging current

250A

Constant current range

550V-600V

Constant power range

600-950V

Protection function

AC lightning protection

Have

Battery reverse connection protection

Have

AC Short Circuit Protection

Have

Over-temperature protection

Have

Anti-island protection

Have

Insulation impedance monitoring

Have